Digital multimeter terminal EL3681
Current
Term. Error
Voltage 
Run LED 
V
COM
10 A
Shield
V
COM
1 A
Shield
Top view 
Contact assembly 

EL3681 | Digital multimeter terminal

The EL3681 EtherCAT Terminal enables measurement of currents and voltages in a wide input range. The measuring ranges are switched automatically, as usual in advanced digital multimeters. For current measurements, two current paths are available, one of which is a high-current path for up to 10 A. The current and the voltage measurement facility can be used for DC and AC. The alternating parameters are output as true RMS values. The measurement readings can be read and processed with EtherCAT. At the same time, the EL3681 enables the measuring type and range to be set via the bus.

Excellent interference immunity is achieved through the fully electrically isolated design of the electronic measuring system and the dual-slope conversion system. High precision and simple, high-impedance measurement from 300 mV to 300 V allow the EtherCAT Terminal to be used like a modern digital multimeter.

In measuring applications in particular, the voltage to be expected is often not yet known during the planning phase. Automatic adjustment of the measurement range simplifies use and reduces stock levels. The selected measuring type and overload are indicated by LEDs.

Technical data EL3681 | ES3681
Number of inputs 1 voltage or 1 current (10 A/1 A)
Technology digital multimeter with automatic range selection
Signal voltage max. 300 V AC/DC, 10 A
Distributed clocks
Internal resistance 3 mΩ/0.2 Ω/12.5 MΩ
Conversion time 0.5 s (1 s during measuring range switching) preset, min. 65 ms
Measured values current, voltage
Measuring voltage 300 mV, 3 V, 30 V, 300 V
Measuring current 100 mA, 1 A and 10 A via high-current path
Resolution 18 bits + sign in each measurement range
Measuring error 0.01 % DC voltage measurement at 25 °C
Measuring procedure DC with arithmetic averaging, AC with true RMS value calculation
Update time 0.5 s, 1 s for measuring range selection
Electrical isolation 1,500 V (terminal/E-bus)
Current consumption power contacts
Current consumption E-bus 150 mA
Bit width in the process image 32 bit data, 16 bit control/status
Special features automatic or manual range selection, 1.25 A fuse installed + spare fuse, filter deactivatable
Weight approx. 70 g
Operating/storage temperature 0…+55 °C/-25…+85 °C
Relative humidity 95 %, no condensation
Vibration/shock resistance conforms to EN 60068-2-6/EN 60068-2-27
EMC immunity/emission conforms to EN 61000-6-2/EN 61000-6-4
Protect. class/installation pos. IP 20/variable
Pluggable wiring for all ESxxxx terminals
Approvals CE
Accessories  
ZB8000-0001 spare fuse, 1.25 A, 10 pieces
Related products  
KL3681 Digital multimeter terminal