EtherCAT Coupler with integrated digital standard and safety I/Os EK1914
Signal LEDs
1…8
Signal LEDs
9…16
Power contact +24 V
Power contact 0 V
+24 V Us 
Input 1 
Input 3 
Output 1 
Output 3 
Safe input 1 
Safe output 1 
0 V Us
Input 2
Input 4
Output 2
Output 4
Safe input 2
 
Safe output 2
Link/Act In
Signal input
EtherCAT
Link/Act Out
Signal output
EtherCAT

EK1914 | EtherCAT Coupler with integrated digital standard and safety I/Os

The EK1914 EtherCAT Coupler combines the functionalities of the EK1100 EtherCAT Coupler with standard and safe digital I/Os. This results in a compact design that is especially suitable for applications with a low number of I/Os. Like the EK1100, the EK1914 can be extended by all EL/ES terminals.

The EK1914 has four digital inputs and four digital outputs as well as two fail-safe inputs and two fail-safe outputs. The EK1914 meets the requirements of DIN EN ISO 13849-1:2008 (Cat 4, PL e).

Technical data EK1914
Task within EtherCAT system coupling of EtherCAT Terminals (ELxxxx) to 100BASE-TX EtherCAT networks
Data transfer medium Ethernet/EtherCAT cable (min. Cat.5), shielded
Distance between stations max. 100 m (100BASE-TX)
Number of EtherCAT Terminals up to 65,534
Delay approx. 1 µs
Data transfer rates 100 Mbaud
Bus interface 2 x RJ45
Safety standard DIN EN ISO 13849-1:2008 (Cat 4, PL e)
Protocol EtherCAT
Safety protocol TwinSAFE/Safety over EtherCAT
Nominal voltage 24 V DC (-15 %/+20 %) (PELV)
Status display 16 LEDs
Number of digital inputs 4 standard and 2 safe inputs
“0“ signal voltage -3…+5 V (EN 61131-2, type 1/3) (standard input)
“1“ signal voltage 11…30 V (EN 61131-2, type 3) (standard input)
Input filter 500 µs (standard input)
Input current typ. 3 mA (EN 61131-2, type 3) (standard input)
Number of digital outputs 4 standard and 2 safe outputs
Load type ohmic, inductive, lamp load
Max. output current per standard input: 0.5 A,
per safe input: 500 mA, min. 20 mA
Output current of clock outputs typ. 10 mA, max. 15 mA
Current supply E-bus max. 500 mA (for higher current consumption use EL9410 power supply terminal)
Power contacts max. 24 V DC, max. 4 A (PELV)
Current consumption typ. 72 mA (excluding current consumption of the sensors/actuators and further terminals on the E-bus)
Power loss typ. 1.8 W without connected sensors/actuators
Electrical isolation between channels: no,
between channels and E-bus: no,
between EtherCAT connections and channels/E-bus: yes
Insulation voltage insulation tested with 500 V DC (between EtherCAT connections and channels/E-bus, under common operating conditions)
Operating/storage temperature 0…+55 °C/-25…+70 °C
EMC immunity/emission conforms to EN 61000-6-2/EN 61000-6-4
Vibration/shock resistance conforms to EN 60068-2-6/EN 60068-2-27
Protect. class/installation pos. IP 20/see documentation
Approvals CE, UL, TÜV SÜD
Accessories  
EL9410 Power supply terminals for E-bus
Cordsets cordsets and connectors